Energy brick is a new type of solar energy storage system. Energy storage is configured differently depending on the needs of the home. The battery capacity is 5.12KWh to 35.84KWh, among which the most suitable for home use is the 10kwh rechargeable Limodish lithium battery. Compared with the Powerwall series, the vertical lithium battery storage system does not need a wall hanging. On top of the battery system, it is a central control system. It monitors the charge and discharge status of each battery. The central control system keeps the input and output stable. Limodish is ideal for home use, green solar energy, saving electricity bills, and providing backup power. Limodish is an excellent battery storage system.
Brief Parameters
NO |
Items |
Parameter |
Remarks |
2.1 |
Rated Capacity |
100Ah (16S1P) |
Discharge:0.2C cut-off voltage:2.7V |
Minimum Capacity |
≥99.5Ah |
||
2.2 |
Energy |
5.12KWh |
|
2.3 |
Nominal Voltage |
48V /51.2V |
|
2.4 |
Open Voltage |
48V~52V |
|
2.5 |
Load Voltage |
≥48V |
|
2.6 |
Internal Impedance |
≤80mΩ |
AC 1KHz after standard charge |
2.7 |
Charge voltage |
58.4V |
|
2.8 |
Standard charge current |
50A |
0.5C |
2.9 |
Max charge current |
100A |
1.0C |
2.10 |
Standard discharge current |
100A |
1C |
2.11 |
Max discharge current |
100A (continuous) |
1C |
2.12 |
Discharge cut-off voltage |
43.2V |
|
2.13 |
Operating Temperature |
0~+60℃ |
Charge |
-20~+60℃ |
Discharge |
||
2.14 |
Storage Temperature |
-20℃~+60℃ |
Less than one month |
-20℃~+30℃ |
Less than six month |
Electrical Performance & Test Condition
NO |
Items |
Criterion |
Testing Methods |
|
1 |
Normal Capacity |
100Ah |
After Normal charge, discharge at 0.33C current to the cut-off voltage. |
|
2 |
Internal Impedance |
≤80mΩ |
Using 1kHz AC internal resistance test instrument under the 50% SOC condition |
|
3 |
Short circuit protection |
Auto cut-off load after short circuit |
Connect the output positive and negative of this battery pack with 0.1Ω resistance. |
|
4 |
Cycle life @DOD100% |
10000+ in lifetime, 3000 above 80% Capacity |
After Normal charging, discharge at 0.33C current to the cut-off voltage, then stand for one hour. Repeat the above process until discharge exceeds 80% of the initial capacity. |
|
5 |
Discharge temperature characteristic @0.33C |
-20℃(6h) |
≥70% |
Capacity @specified temperature/Capacity @ 25℃=the percentage accord with criterion
|
0℃(6h) |
≥80% |
|||
25℃(4h) |
≥100% |
|||
55℃(4h) |
≥95% |
|||
6 |
Capacity retention rate |
≥96% remaining capacity |
After regular charging and open circuit for 28days at 25±5℃, discharging capacity shall meet the test requirements with 0.33C constant current discharge to cut-off voltage. |
Circuit Protection Specifications
No |
Item |
Content |
Criterion |
4.1 |
Overcharge |
Over-charge protection for each cell |
3.7±0.025V |
Over-charge release for each cell |
3.6±0.05V |
||
Over-charge release method |
Under the release voltage |
||
4.2 |
Over-discharge |
Over-discharge protection of each cell |
2.70±0.08V |
Over-discharge release for each cell |
2.80±0.1V |
||
Over-discharge release method |
recovering charge |
||
4.3 |
Over Current |
charge over current protection |
105A Alarm,110A protection process starts |
Discharge over current protection |
105A Alarm,110A protection process starts |
||
Short circuit protection |
Yes |
||
4.4 |
Temperature |
Charge over temperature protection |
65±3℃ protection process starts: |
Charge under temperature protection |
-0±3℃ protection process starts; |
||
Discharge over temperature protection |
65±3℃ protection process starts: |
||
Discharge under temperature protection |
-20±3℃ protection process starts: |